Motor protection switches

- These switches can be used for changing the sense of rotation or as star-delta or polarity switches
- Overload protection
- Overcurrent protection (optional)
- Flush-mounting in plastic or aluminium enclosures possible
- Special types on request.

Image

Wyłączniki ochronne dla silników Elektra

Motor protection On/Off switches / EM series

EM series motor protection On/Off switches can be supplied in 10 setting ranges from 0.3 to 16 amps. In addition to thermal triggering, the switch can also be supplied with quick KA magnetic triggering or UA low-voltage triggering. Operation by means of insulated T-handle is via a robust switching latch with rotary drive. In the version with low-voltage triggering the EM switches ensure the protection called for in the DIN EN 60204 Part 1 provisions against automatic restarting when power is restored following a power cut. The nominal frequency is 50 Hz. Switches for other voltages with a frequency of 50 or 60 Hz can also be supplied on request.

 

Motor protection cam switches / MN series

The MN series motor protection switches are cam switches with thermal over-current trip devices integrated within the switch. The base unit forms the contact chamber with the cam wheel for function control. In the event of excess current, the bi-metals cause the switching latch to be operated via a trip shaft. This interaction enables a multitude of switching programmes with integrated motor protection to be produced. Due to the switching of the bi-metals within the current circuit there are 2 different series in terms of the setting ranges: for On/Off switches, reversing switches, pole-changing switches (1 rotary speed protected) and single-phase starter switches 12 setting ranges of 0.3 to 21.5 amps have been defined.

 

Motor protection star-delta switches / MN series

The star-delta switches are sub-divided into 7 setting ranges of 2.85 to 37 amps, with the bi-metals wired up in such a way that they are in the motor's phase current circuit. The motor coil is thus protected both in the star and the delta position. The current to be set on the setting scale is the motor's rated current. Star-delta switches for extremely difficult starting up are used where - due to the drive system - a long start-up period in the star position is required. So that the motor protection is not triggered during the start-up phase, the bi-metals are placed such that only in the delta position are they connected up in the current circuit. With this form of switching the motor is thus protected only in the delta position.

 

Machine and device protection switches / F/FM series

The machine and device protection switch has been developed for use with standard machines up to a power output level of 4kW in AC-3 at 400V. The combination options of thermal and/or low-voltage triggering enables the appropriate selection of protection function to be offered in connection with the different designs. Even if the handle is jammed, the switch trips via a robust switching latch and prevents any starting up again.

Image
Image
Image
Image
Image
Image