Emergency stop modules


Image

Table of available emergency switch modules

TypeDescriptionPossibility of using as gate and latch controllerPerformance level according to EN 13849-1Performance level according to EN 13849-1SIL Claimed Level to EN 62061Number of channelsMax. number of outputs (C/O = changeover, NO = normally open)Maximum thermal current Lth (A)Short circuit detectionNominal voltageType of terminalModule width (mm)Data Sheet
Nominal voltage
NI 5061emergency stop device1 NO, 2 NC442
NI5061.pdf
LG 5924emergency stop module4 / d214 NO5++removable screw / cage clap terminals22.5
LG5924.pdf
LG 5925emergency stop module++4 / e31.24 NO5+++removable screw / cage clap terminals22.5
LG5925.pdf
BG 5924, IP 5924emergency stop module4 / e314 NO7++removable screw terminals22.5; 70
BG5924, IP5924.pdf
RK 5942emergency stop module, compact housing4 / e311 NO5+screw17.5
RK5942.pdf
BD 5987emergency stop module+4 / e31.22 NO10+++screw45
BD5987.pdf
BG 5925emergency stop module+4 / e31.23 NO7+++removable screw terminals22.5
BG5925.pdf
BN 5983emergency stop module+4 / e31.23 NO, 1 NC10++removable screw terminals100
BN5983.pdf
BD 5935emergency stop module+4 / e31.23 NO, 1 NC10+++removable screw terminals45
BD5935.pdf
LG 5928 emergency stop module, with time delay up to 300 s+4 / e31.22 NO, 1 NO - including with time delay8++removable screw / cage clap terminals22.5
LG5928.pdf
BH 5928emergency stop module, with time delay up to 300 s+4 / e31.23 NO, 3 NO - including with time delay5++removable screw terminals45
BH5928.pdf
BI 5928emergency stop module, with time delay up to 300 s+4 / e31.23 NO, 3 NO - including with time delay5++removable screw terminals67.5
BI5928.pdf
BH 5903emergency stop module, with voltage failure detection4 / e31.23 NO5++removable screw terminals90
BH5903.pdf
BL 5903emergency stop module, with voltage failure detection4 / e31.23 NO5++removable screw terminals90
BH5903.pdf
BN 5930.48/203, BN 5930.48/204emergency stop module+4 / e31.23 NO, 1 NC10++removable screw terminals100
BN5930_48_203, BN5930_48_204.pdf
LG 5925/034emergency stop module for elevator controls4 / e31.23 NO, 1 NC2+++removable screw / cage clap terminals22.5
LG5925_034.pdf
BG 5925/034emergency stop module for elevator controls4 / e31.23 NO8+++removable screw terminals22.5
BG5925_034.pdf

Table of available safety controllers

TypeDescriptionMax. number of inputsNumber of channelsNominal voltage 24 VDCModule width (mm)Data Sheet
BH 5922safety controllers81.2+45
BH5922.pdf
BL 5922safety controllers161.2+90
BL5922.pdf