DOLD special-purpose measuring relays, available from ELTRON, are advanced devices designed for non-standard applications that require exceptional reliability and compliance with stringent standards. They are used, among others, in power generation systems, emergency power supply, medical infrastructure and renewable energy.
The ELTRON range includes, among others:
DOLD relays for special applications, offered by ELTRON, meet the highest quality and safety standards. They enable flexible integration into existing infrastructure and effective protection of critical points in the installation.
Table of available monitors for special applications
Type | Description | Designed for systems | Measuring range | Outputs (C/O = changeover, NO = normally open) | Response delay adjustment | Required supply voltage | Enclosure width (mm) | Data Sheet |
RP 9800 | voltage and frequency monitor for generator sets on public grid | 3-phase | 50 Hz, AC 230 V | 2 C/O | + | 70 | ![]() RP9800.pdf | |
RP 9810 | voltage and frequency monitor for generator sets on public grid according to VDE-AR-N 4105 | 3-phase | 50 Hz, AC 400 / 230 V | 3 C/O | + | 70 | ![]() RP9810.pdf | |
RP 9811 | voltage and frequency monitor for generator sets on public grid according to many countries’ standards | 3-phase | AC 400 / 230 V | 3 NO | + | + | 70 | ![]() RP9811.pdf |
MK 9143N, MH 9143 | Frequency monitor for generator sets on public grid | 1-phase | 50 / 60 Hz | 2 C/O, 4 C/O | + | + | 22.5, 45 | ![]() MK9143N, MH9143.pdf |
IP 9109.27/107 | voltage relay, undervoltage protection, for medical applications, according to DIN VDE 0100-710 | 1-phase | AC 230 V | 2 C/O | + | 70 | ![]() IP9109_27_107.pdf | |
IP 9109.17/107 | voltage relay, undervoltage protection, for medical applications, according to DIN VDE 0100-710 | 1-phase | AC 230 V | 2 NO + | + | 70 | ![]() IP9109_17_107.pdf | |
IP 9110/107 | voltage relay, undervoltage protection, for medical applications, according to DIN VDE 0100-710 | 3-phase | AC 400 V | 1 NO + | + | 70 | ![]() IP9110_107.pdf | |
IN 5880/710, IN 5880/711 | Insulation monitor for medical applications, according to DIN VDE 0100-710 | 1-phase | 50 ... 500 k | 2 C/O | + | 52.5, 70 | ![]() IN5880_710, IN5880_711.pdf | |
IR 9112/710, IS 9112/711, IS 9112/712 | Insulation current and temperature monitor in IT networks for medical applications, according to DIN VDE 0100-710 | 1-phase | 500 k | 3 x 2 C/O | + | + | 105, 140 | ![]() IR9112_710, IR9112_711, IR9112_712.pdf |
BA 9054/331, BA 9054/332 | battery symmetry monitor, undervoltage, short circuit and battery system sulfation protection | 1-phase | 0.12...1.2 V DC | 2 C/O | + | + | 45 | ![]() BA9054_331, BA9054_332.pdf |
IK 9076, SK 9076 | Current and wire breakage monitor | 1-phase | < 0,7A | 1 C/O | + | 17.5 | ![]() IK9076, SK9076.pdf | |
IP 9111/107 | transformer protection module, current and temperature control, for medical applications, according to DIN VDE 0100-710 | 1-phase | 5 … 50 A, > 3.8 k | 2 x 2 C/O | + | 70 | ![]() IP9111_107.pdf | |
BO 5877/011 | motor voltage monitor for wind power plant applications | 3-phase | 400 V, 2 M | 1 NO | + | + | 90 | ![]() BO5877_011.pdf |
The offer also includes:
Type | Description | Enclosure width (mm) | Data Sheet |
AI940 | protective relay, circuit breakage when amperage is too high | 45 | ![]() AI940.pdf |