74040


Image

60W 5-12/5-12V 4-output ETD29 Flyback Transformer.

Features

  • Primary/Secondary Insulation >= 4000V
  • Primary Auxiliary Insulation >= 1500V
  • Creepage Distance Primary/Secondary >= 8mm
  • Ambient Temperature < 50°C
  • Construction confirms to CEI950, CEI335, CEI61558 for reinforced insulation
  • Exclusively uses UL94-VO listed materials
Power60  
SizeETD29  
Number of Outputs4  
Max Output Power60  
Frequency (multiple)100 / 66 / 132 kHz  
Control IC manufacturer (Multiple)Infineon / Infineon / Motorola / Motorola / Power Integrations / Power Integrations / ST Microelectronics / ST Microelectronics  
Control IC P/N (Multiple)TDA16834 / TDA16834 / MC33372 / MC33372 / TOP245Y / TOP245Y / VIPer50 / VIPer50  
Inductance500 μH