Universal measuring transducers with isolation

Image

P 32000

Image

The PolyTrans P 32000 universal transmitters provide connection possibilities for all standard thermocouples, resistance ­thermometers, strain gauges, full bridges, resistors and potentiometers/resistive sensors. They can be flexibly adapted to the respective measuring task using DIP and rotary encoder switches or via an IrDA interface. The broad-range power supply covers all common supply voltages from 110 to 230 V AC and ensures maximum safety even with unstable power grids.

3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimum protection of personnel and equipment as well as unaltered transmission of measurement signals.
The PolyTrans P 32000 offer maximum performance in the smallest of spaces. Resistance thermometers can be operated in 2-, 3- or 4-wire configuration. The connection configuration is automatically recognized, adjustment is not required. All commercial ­thermocouples can be read with internal or external ­reference junction compensation. To detect mechanical quantities such as force or strain, strain gauges can be connected in full-bridge configuration.

The ability to connect variable resistors and potentiometers creates a wide range of application possibilities, for example in the ­field of displacement or position detection. Input voltage signals up to +/– 1000 mV are converted into 0/4 to 20 mA or 0 to 10 V standard signals. This enables low-cost implementation of current measurements using shunt ­resistors, for example.
Knick offers the PolyTrans P 32000 transmitter with SIL approval for applications with high demands on functional safety. The requirements of EN 61508 were implemented through specially developed hardware and software. The implemented fail-safe concept makes use of structural measures at the device level (redundancy of system components) and diagnostic ­methods for selective fault detection. The product is SIL2 approved (EN 61508) by an authorized body (TÜV Rheinland). SIL3 in redundant implementations.

The Facts

• Universal usability from simple to challenging measurement tasks
  with all known temperature sensors, strain gauges, potentiometers,
  and similar sensors
• Convenient setting of all parameters via IrDA interface
  - uncomplicated, menu-guided adjustment also »on site«
  including archiving of the configuration data
• Intuitive configuration of the basic parameters
  - easily, without tools, using 4 rotary and 8 DIP switches
• Calibrated range selection
  - no complicated adjusting
• Automatic detection of the sensor connection (2-, 3- or 4-wire)
• Simulation of any desired output values for correct installation/commissioning
• World-wide usability due to 110 V AC to 230 V AC broad-range power supply
• Protective separation according to EN 61140:  protection of the maintenance staff
  and subsequent devices against excessively high voltages up to 300 V AC/DC
• Functional safety up to SIL 2 (up to SIL 3 in the case of redundant configuration)
  with TÜV certificate, systematically developed according to EN 61508
• High accuracy due to innovative circuit design
• Reduced inventory: one transmitter covers all conceivable tasks
• Minimum space consumption in the enclosure
• 5-year warranty

P 32100

Image
The universal ThermoTrans P 32100 temperature transmitters provide connection possibilities for all common thermocouples and resistance thermometers. They can be flexibly adapted to the respective measuring task using DIP and rotary encoder switches or via an IrDA port. The broad-range power supply covers all common supply voltages from 110 to 230 V AC and ensures maximum safety even with unstable power grids. 3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimal protection of personnel and equipment as well as unaltered transmission of the measurement signals. The ThermoTrans P 32100 offer maximum performance in the smallest of spaces.
Resistance thermometers can be operated in 2-, 3- or 4-wire configuration. The connection configuration is automatically recognized, adjustment is not required. All standard thermocouples can be read with internal or external reference junction compensation.
Input voltage signals up to +/- 1000 mV are converted into 0/4 to 20 mA or 0 to 10 V standard signals. This enables low-cost implementation of current measurements using shunt resistors, for example.
Special measuring tasks can be solved with ThermoTrans devices which Knick configures according to individual specifications. Fixed-range devices without switches are used, for example, when manipulations or mix-ups must be precluded.
For applications requiring a high level of functional safety, Knick offers the ThermoTrans
P 32100 transmitter with SIL approval. The requirements of EN 61508 were implemented through specially developed hardware and software. The fail-safe concept makes use of structural measures at the device level (redundancy of system components) and diagnostic methods for selective fault detection. The product is SIL 2 approved (EN 61508) by an authorized body (TÜV Rheinland). SIL-3 in redundant implementations.
 
Facts
• Universal usability from simple to challenging measurement tasks
  with all known temperature sensors
• Convenient setting of all parameters via IrDA interface
- uncomplicated, menu-guided adjustment also »on site« including archiving
  of configuration data
• Intuitive configuration of the basic parameters 
- easy, without tools, using 4 rotary and 8 DIP switches
• Calibrated range selection 
- no complicated adjusting
• World-wide usability due to 110 V AC to 230 V AC broad-range power supply
• Automatic detection of the sensor connection (2-, 3- or 4-wire)
• Protective separation according to EN 61140 
- protection of maintenance staff and subsequent devices against excessively
  high voltages up to 300 V AC/DC
• Functional safety up to SIL 2 (up to SIL 3 in case of redundant configuration)
  with TÜV certificate 
- systematically developed according to EN 61508
• High accuracy due to innovative circuit design
• Minimum space consumption in the enclosure 
- modular housing: just 6 mm wide 
- more transmitters per meter of DIN rail
• Low-cost assembly 
- quick mounting, convenient connection of power supply through DIN rail bus connectors
  (in case of 24 V DC power supply)
• 5-year warranty

A 20210

Image
The flexible ThermoTrans A 20210 temperature transmitters provide connection possibilities for most of the common thermocouples and resistance thermometers. They can be flexibly adapted to the respective measuring task by the user using DIP and rotary encoder switches. 3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimal protection of personnel and equipment as well as unaltered transmission of the measurement signals. The ThermoTrans A 20210 offer maximum performance in the smallest of spaces.
Resistance thermometers can be operated in 2-, 3-, or 4-wire configuration. The connection configuration is automatically recognized, adjustment is not required. Thermocouples can be read with internal or external reference junction compensation.
Input voltage signals up to +/- 1000 mV are converted into 0/4 to 20 mA or 0 to 10 V standard signals. This enables low-cost implementation of current measurements using shunt resistors, for example.
Special measuring tasks can be solved with ThermoTrans devices which Knick configures according to individual specifications. Fixed-range devices without switch are used, for example, when manipulations or mix-ups must be precluded.
 
Facts
• Flexible application with common temperature sensors:
  Pt100, Pt1000, Ni100, type J and K thermocouples
• Intuitive and easy configuration without tools, using 4 rotary and 8 DIP switches
• Calibrated range selection 
- no complicated adjusting
• Automatic detection of the sensor connection (2-, 3- or 4-wire)
• Protective separation according to EN 61140 
- protection of the maintenance staff and subsequent devices against excessively
  high voltages up to 300 V AC/DC
• High accuracy due to innovative circuit design
• Minimum space consumption in the enclosure 
- modular housing: just 6 mm wide 
- more transmitters per meter of DIN rail
• Low-cost assembly
- quick mounting, convenient connection of the power supply
  through DIN rail bus connectors
• 5-year warranty

P 32200

Image

The universal SensoTrans DMS P 32200 strain gauge transmitters provide connection possibilities for all standard strain gauge force transducers and strain gauge load cells in full bridge configuration. They can be flexibly adapted to the respective measuring task using DIP and rotary encoder switches or via an IrDA® port. The broad-range power supply covers all common supply voltages from 24 to 230 V and ensures maximum safety even with unstable power grids. 3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimal protection of personnel and equipment as well as unaltered transmission of the measurement signals. The SensoTrans DMS P 32200 offer maximum performance in the smallest of spaces. Adjusting the zero point and sensitivity to the individual strain gauge sensor is particularly convenient via the infrared port, for example using a PDA. Sensors with known characteristics can be very easily calibrated using 4 rotary encoder switches and 8 DIP switches. Special measuring tasks can be solved with SensoTrans devices that Knick configures according to individual specifications. Fixed-range devices without switches are used, for example, when manipulations or mix-ups must be precluded. Knick offers the SensoTrans DMS P 32200 transmitter with SIL approval for applications with high demands on functional safety. The requirements of EN 61508 were implemented through specially developed hardware and software. The implemented fail-safe concept makes use of structural measures at the device level (redundancy of system components) and diagnostic methods for selective fault detection. The product is SIL 2 approved (EN 61508) by an authorized body (TÜV Rheinland). SIL-3 in redundant implementations.

Facts
• Universal usability for strain gauges, pressure and load cells,
  and other resistive measuring bridges
• Convenient setting of all parameters via IrDA interface 
- uncomplicated, menu-guided adjustment also “on site“ including
  archiving of the configuration data
• Intuitive configuration of the basic parameters 
- easy, without tools, using 4 rotary and 8 DIP switches
• Calibrated range selection 
- no complicated trimming
• Convenient adjustment 
- zero point and sensitivity adjustable via IrDA® port
• Simulation of any desired output values for correct installation/commissioning
• World-wide usability due to 110 V AC to 230 V AC broad-range power supply
• Protective separation according to EN 61140 
- protection of the maintenance staff and subsequent devices
  against excessively high voltages up to 300 V AC/DC
• Functional safety up to SIL 2 (up to SIL 3 in case of redundant configuration) with
  TÜV certificate 
- systematically developed according to EN 61508
• High accuracy due to innovative circuit design
• Minimum space consumption in the enclosure 
- modular housing: just 6 mm wide 
- more transmitters per meter of DIN rail
• Low-cost assembly 
- quick mounting, convenient connection of power supply through DIN rail bus connectors
  (in case of 24 V DC power supply)
• 5-year warranty

A 20220

Image

The universal SensoTrans DMS A 20220 strain gauge transmitters provide connection possibilities for all standard strain gauge force transducers and strain gauge load cells in full bridge configuration. They can be flexibly adapted to the respective measuring task by the user via DIP and rotary encoder switches or a “teach-in function“. 3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimum protection of personnel and equipment as well as unaltered transmission of measurement signals. The SensoTrans DMS A 20220 offer maximum performance in the smallest of spaces. Adjusting the zero point and sensitivity to the individual strain gauge sensor is particularly convenient using the “teach-in function“ just at the push of a button on the front of the device. Sensors with known characteristics can be very easily calibrated using 4 rotary encoder switches and 8 DIP switches.Special measuring tasks can be solved with SensoTrans devices that Knick configures according to individual specifications. Fixed-range devices without switches are used, for example, when manipulations or mix-ups must be precluded.

Facts
• Universal usability for strain gauges, pressure and load cells,
  and other resistive measuring bridges
• Intuitive configuration of the basic parameters 
- easy, without tools, using 4 rotary and 8 DIP switches
• Calibrated range selection 
- no complicated trimming
• Convenient adjustment 
- Zero point and sensitivity are directly adjusted “at the push of a button“
  using the teach-in function
• Protective separation according to EN 61140 
- protection of maintenance staff and subsequent devices against
  excessively high voltages up to 300 V AC/DC
• High accuracy due to innovative circuit design
• Minimum space consumption in the enclosure 
- modular housing: just 6 mm wide 
- more transmitters per meter of DIN rail
• Low-cost assembly 
- quick mounting, convenient connection of power supply through DIN rail bus connectors
• 5-year warranty

R P 32300

Image
The universal SensoTrans R P 32300 resistance transmitters provide connection possibilities for all standard potentiometers for angle, path or position detection up to 50 kohms. They can be flexibly adapted to the respective measuring task using DIP and rotary encoder switches or via an IrDA® port. The broad-range power supply operates over a range of 110 to 230 V AC and ensures maximum safety even with unstable power grids. 3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimal protection of personnel and equipment as well as unaltered transmission of the measurement signals.
The SensoTrans R P 32300 offer maximum performance in the smallest of spaces. Adjusting the start and end value to the individual position sensor is particularly convenient via the infrared interface, for example using a PDA. Sensors with known characteristics can be very easily calibrated using 4 rotary encoder switches and 8 DIP switches.
Special measuring tasks can be solved with SensoTrans devices that Knick configures according to individual specifications. Fixed-range devices without switches are used, for example, when manipulations or mix-ups must be precluded.
Knick offers the SensoTrans R P 32300 transmitter with SIL approval for applications with high demands on functional safety. The requirements of EN 61508 were implemented through specially developed hardware and software. The implemented fail-safe concept makes use of structural measures at the device level (redundancy of system components) and diagnostic methods for selective fault detection. The product is SIL 2 approved (EN 61508) by an authorized body (TÜV Rheinland). SIL 3 in redundant implementations.

Facts

• Universal usability with potentiometers, resistive sensors, remote resistance transducers,
  and similar sensors
• Convenient setting of all parameters via IrDA port
  - uncomplicated, menu-guided adjustment also »on site«
  including archiving of the configuration data
• Intuitive configuration of basic parameters
  - easy, without tools, using 4 rotary and 8 DIP switches
• Calibrated range selection
  - no complicated trimming
• Convenient adjustment
  - zero point and sensitivity adjustable via IrDA port
• Simulation of any desired output values for correct installation/commissioning
• World-wide usability due to 110 V AC to 230 V AC broad-range power supply
• Protective separation according to EN 61140 - protection of the maintenance staff
  and subsequent devices against excessively high voltages up to 300 V AC/DC
• Functional safety up to SIL 2 (up to SIL 3 in case of redundant configuration)
  with TÜV certificate
  - systematically developed according to EN 61508
• High accuracy due to innovative circuit design
• Minimum space consumption in the enclosure
  - only 6 mm wide modular housing
  - more transmitters per meter of mounting rail
• Low-cost assembly
  - quick mounting, convenient connection of the power supply through DIN rail bus connectors
  (in case of 24 V DC power supply)
• 5-year warranty

R A 20230

Image

The flexible ThermoTrans A 20210 temperature transmitters provide connection possibilities for all standard potentiometers for angle, path, or position measurement up to 50 kohms. They can be flexibly adapted to the respective measuring task by the user using DIP and rotary encoder switches. 3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimal protection of personnel and equipment as well as unaltered transmission of the measurement signals. The ThermoTrans A 20210 offer maximum performance in the smallest of spaces.
Resistance thermometers can be operated in 2-, 3- or 4-wire configuration. The connection configuration is automatically recognized, adjustment is not required. Thermocouples can be read with internal or external reference junction compensation.
Input voltage signals up to +/- 1000 mV are converted into 0/4 to 20 mA or 0 to 10 V standard signals. This enables low-cost implementation of current measurements using shunt resistors, for example.
Special measuring tasks can be solved with ThermoTrans devices which Knick configures according to individual specifications. Fixed-range devices without switches are used, for example, when manipulations or mix-ups must be precluded.

Facts
• Universal usability with potentiometers, resistive sensors, remote resistance transducers
  and similar sensors
• Intuitive and easy configuration without tools, using 4 rotary and 8 DIP switches
• Calibrated range selection 
- no complicated adjusting
• Automatic detection of the sensor connection (2-, 3- or 4-wire)
• Protective separation according to EN 61140 
- protection of the maintenance staff and subsequent devices against excessively
  high voltages up to 300 V AC/DC
• High accuracy due to innovative circuit design
• Minimum space consumption in the enclosure 
- modular housing: just 6 mm wide 
- more transmitters per meter of DIN rail
• Low-cost assembly
- quick mounting, convenient connection of power supply through DIN rail bus connectors
• 5-year warranty