The Tico 732 stands out as a result of its versatility and its multifunctional ability as a counter with up to two presets, as a tachometer, timer, shift or batch counter. The voltage supply is either 12 to 24 volts DC, 24 volts AC, 115 volts AC or 230 volts AC. The 6-digit display is noticeably easy to read and is available as either an LCD or an LED display. The device offers many programming options, has an integrated totalizing counter and is equipped with a keypad locking function. 

Image
  • Very easy operation
  • LED or LCD display
  • Up to two presets
  • Prescaler 0.001 - 999.999

 

General

Product Family tico 732
Function Multifunctional counter
Technology Electronic
Digits 6-digit
Display
  • 6-digit
  • count reading / preset
  • leading zero suppression
  • decimal point
Preset
  • 1 preset
  • 2 presets
  • without presets
Digit Height [mm]
  • LCD 9 mm (0.4 in)
  • LED 7.6 mm (0.3 in)
Display Variant
  • LCD
  • LED

 

Electrical

Voltage
  • 12-24 VDC
  • 24-230 VAC
Reset
  • manual reset
  • electrical reset
Signal Times 0.02 s to 1 s or bistable
Current Consumption [mA]
  • 12-24 VDC, LCD: <100 mA
  • 12-24 VDC, LED: 150 mA
  • 24 VAC: <250 mA
  • 100 VAC: < 60 mA
  • 115 VAC: <50 mA
  • 230 VAC: <25 mA each, incl. power to sensor
Input Resistance approx. 10 k? (static)
Pulse Length min.
  • 17 ms (30 Hz)
  • 100 ?s (5 kHz)
Supply Voltage
  • 12-24 VDC
  • 24, 100, 115, 230 VAC
Count Frequency [Hz] max. 5 kHz (2,5 kHz using 2 channels)
Sensor Supply
  • 12 - 30 VDC
  • max. 50 mA
Storage of Values NVM> 10 years
Electrical Connection screw terminals
Amplitude Threshold
  • < 2 V and> 8 V or < 2 V and
  • > 3.8 V at TTL levels
  • max. 40 VDC
Active Edge programmable, positive with PNP input, negative with NPN input
Pulse Shape any square wave (1:1 for max. frequency)
Prescaler from 0.001 to 999.999 programmable
Relay (Preset 1 and 2)
  • Varistor max. 250 VAC / 30 VDC
  • min. 5 V AC/DC
  • max. 5A
  • min. 10 mA
  • delay < 10 ms
Transistor output (Preset 1 + 2)
  • DC supply: PNP
  • active high
  • VDC-2V (supply voltage-2 V)
  • max. 30 mA
  • transformer version:PNP
  • active high
  • 12-30 VDC
  • max. 30 mA

 

Tachometer

Measuring Principle (tachometer) period measurement (1/tau)
Display Range 1/min or 1/sec
min. Frequency 0.125 Hz = 8 sec
Limit Values 2 alarms with programmable start suppression

 

Time counter

Time Base (Tachometer)
  • programmable, sec
  • min
  • h or hh.mm.ss
Measuring Principle (timer) pulse width or period duration measurement (start-stop)
Function Time Counter single pulse measurement (short meter) or cumulative measurement (hour meter)
Resolution programmable 1, 0.1, 0.01, 0.001

 

Environment and security

IP Protection Class IP 65
Operating Temperature [°C] 0 ... + 50 °C (+ 32 ... 122 °F)
Storage Temperature [°C] –- 20 ...… + 70 °C (+ 14 ... 122 °F)
Degree of Protection
  • front IP 65
  • connections IP 20
Cable Length < 30 m
General Design EN 61 010-1 / IEC 61010-1
Approvals UL + CUL E 96 337
Vibration Resistance 10 m/s² (33 ft/s²) (10 ... 150 Hz) acc. IEC 68-T2-6
Shock Resistance 100 m/s² (328 ft/s²) (18 ms) acc. IEC 68-T2-27
Protection Class II, EN 61010-1 / IEC 61010-1
Contamination Level
  • V 2
  • EN 50178

 

Mechanical

Size [mm] 48x48x108
Mounting Options Clamping frame
Mounting with clamping frame
Reset
  • manual reset using keypad
  • external reset
  • static or dynamically programmable
  • pulse duration> 5 ms
  • automatic reset after main preset has been reached (programmable)