446/447

Image

The user-friendly Type 446-447 is an electronic subtracting preset counter. It is equipped with a 3 or 5-digit display stand. Depending on the version, Type 446-447 offers manual, electric or even optional automatic reset. As the main product in this family, it is a plug-and-play device and can easily be combined with other counters in the modular 400 series.

Image
  • Reset manual or electric
  • Display 3 or 5-digit
  • Plug-and-play in Modular System 400

 

General

Product Family 446/447
Function Preset counter
Technology Electromechanical
Digits
  • 3-digit
  • 5-digit
Display
  • 3-digit
  • 5-digit
Preset 1 preset
Digit Height [mm] 4 mm (0.2 in)

 

Electrical

Voltage
  • 12 - 220 VDC
  • 24 - 230 VAC
Reset
  • lockable reset
  • electrical reset
Signal Times from when preset has been reached until reset
Duty Cycle at 25 °C
  • DC: counter 100 %, reset magnet: 20%, max. 2 min.
  • AC: counter 100%, reset magent: 10 %, max. 1 min
Duty Cycle at 50 °C counter 50 % max. run time 10 min
Pulse Duty Factor Reset Impulse
  • 1:5
  • 1:10
Power Consumption
  • DC: counter 2.5 W
  • reset magnet 12 W
  • AC: counter 2.75 VA
  • reset magnet 16 VA
Pulse Length min.
  • DC: counter 20 ms
  • reset magnet 200 ms
  • AC: counter 50 ms
  • reset magnet 200 ms
Residual Ripple [%] DC: 48 %
Supply Voltage
  • 12, 24, 48, 110, 220 VDC
  • 24, 115, 230 VAC
Contact Type floating changeover contact
Switching Voltage max. 220 V AC
Switching Current
  • max. 20 VA / 1 A
  • non-inductive
Count Frequency [Hz]
  • DC: counter 25 Hz
  • reset magnet 1 per s
  • AC: counter 10 Hz
  • reset magnet 1 per 2 s
Count Input subtracting
Pulse Duty Factor Count Impulse
  • DC: counter 1:1
  • reset magnet: 1:10
  • AC: counter 1:1
  • reset magnet: 1:10
Reset Frequency
  • DC: max. 1 per s
  • AC: max. 1 per 2 s
Electrical Connection AMP connector plug 0.8 x 2.8 mm (0.3 x 1.1 in) (via connection box)

 

Counter

Maintenance-Free operation
  • counter 2 x 10? pulses
  • reset magnet 1.5 x 10? pulses

 

Environment and security

IP Protection Class IP 30
Operating Temperature [°C] –- 10 ...… + 50 °C (+ 14 ... 122 °F)
Storage Temperature [°C] –- 40 ...… + 85 °C (+ 14 ... 122 °F)
Degree of Protection
  • front IP 30
  • connections IP 00
  • for a higher protection class, we recommend a protective case with transparent cover (see Accessories)
General Design EN 61 010-1 / IEC 61010-1
Protection Class II, EN 61010-1 / IEC 61010-1
Contamination Level
  • V 2
  • EN 50178

 

Mechanical

Size [mm] 50x50x76
Mounting Options Modular system 400
Mounting Can be combined in modular system 400
Reset
  • manual and electrical reset
  • key reset
Weight [g] approx. 145 g (3.2 oz)
Mounting Position horizontal rolling axis